AZ-409 (3pt) — FT-P-01 still-image frame-center accuracy: - accuracy_evaluator.py: GT loader + Vincenty error + AC-2/AC-3 pass-counts - test_ft_p_01_still_image_accuracy.py: scenario gated on frame_source_replay + sitl_observer NotImplementedError; AC-4 timeout discipline AZ-412 (3pt) — FT-P-04 Derkachi f2f registration >=95% on normal segments: - registration_classifier.py: accel-derived attitude + overlap heuristic + success ratio with AC-3 sharp-turn exclusion - test_ft_p_04_derkachi_f2f_registration.py: scenario gated on frame_source_replay + imu_replay + fdr_reader AZ-413 (3pt) — FT-P-05 + FT-P-06 cross-domain MRE budgets: - mre_evaluator.py: per-image budget (strict <2.5px) + 95th-percentile via numpy linear interp + combined report - test_ft_p_05_sat_anchor.py: cross-domain scenario, reuses accuracy_evaluator for geodesic join - test_ft_p_06_mre_budgets.py: pure piggyback on FT-P-04 + FT-P-05 CSV evidence; skips when either upstream CSV missing Tests: 325 unit tests pass (+77 vs batch 69). Reports: batch_70_report.md, batch_70_review.md (PASS). Co-authored-by: Cursor <cursoragent@cursor.com>
9.0 KiB
Batch 70 Report — Test Implementation (cycle 1, batch 4 of test phase)
Batch: 70
Date: 2026-05-16
Context: Test implementation (greenfield Step 10 — Implement Tests)
Tasks: AZ-409 (3pt), AZ-412 (3pt), AZ-413 (3pt) — 9 cp / 3 tasks
Cycle: 1
Verdict: COMPLETE — PASS (self-reviewed; see reviews/batch_70_review.md)
Summary
Three pure-positive scenarios on the same Derkachi + still-image fixtures that AZ-407 / AZ-408 set up. Each follows the now-established batch-69 pattern:
- A pure-logic helper module under
e2e/runner/helpers/(everything the scenario needs except docker-bound replay + observation). - A scenario file under
e2e/tests/positive/parameterized across(fc_adapter, vio_strategy)and skip-gated on upstream helperNotImplementedError(auto-activates when the harness lands). - A unit-test file under
e2e/_unit_tests/helpers/that drives the helper directly with synthetic + real-fixture data.
AZ-409 — FT-P-01 still-image frame-center accuracy (3pt)
runner/helpers/accuracy_evaluator.py—load_gt_coordinatesparses_docs/00_problem/input_data/coordinates.csv;evaluatejoins byimage_id, computes Vincenty geodesic distance viageo.distance_m, and produces per-image + aggregate reports. The three thresholds are exposed as module constants (PASS_COUNT_50M_REQUIRED=48,PASS_COUNT_20M_REQUIRED=30,TOTAL_IMAGES_REQUIRED=60) so a future spec change has exactly one place to flip.AggregateReport.overall_passis the boolean the scenario asserts.tests/positive/test_ft_p_01_still_image_accuracy.py— pytest scenario, gated onframe_source_replay.replay_image_directory+sitl_observer.get_observer. Pushes one image at a time with a 5 s per-image timeout; timeouts are recorded as(inf, inf)and propagate topass_50m=false,pass_20m=false,error_m=infper AC-4.- 20 unit tests in
test_accuracy_evaluator.py.
AZ-412 — FT-P-04 Derkachi frame-to-frame registration ≥95 % (3pt)
runner/helpers/registration_classifier.py— derives bank + pitch from SCALED_IMU2 accelerometer (spec-mandated; AC-1 prohibits internal SUT attitude). The classifier expands each 10 Hz IMU row into 3 video-frame indices (30 fps / 10 Hz = 3), classifies each frame as normal iff bank/pitch ∈ ±10° AND inferred prior-frame overlap ≥40 %, then exposes acompute_success_ratio(classifications, registration_success_by_frame)that returns a typedSuccessReportwithexcluded_by_{attitude,overlap,missing_metric}counts so AC-3 diagnostics survive in the run report.- Inferred-overlap heuristic — translation = horizontal velocity ×
(1/30 s); overlap =
1 - translation / ground_footprint_mclamped to [0, 1]; default ground footprint = 147 m (derived from the camera_info.md ~141 m altitude × 55° HFOV). The heuristic is explicitly an upper bound; the docstring records the assumption so a future calibration change has the tunable in one place. tests/positive/test_ft_p_04_derkachi_f2f_registration.py— gated onframe_source_replay,imu_replay,fdr_reader. Reads per-frameregistration_successfromframe_metricFDR records; emitsft-p-04-{fc_adapter}-{vio_strategy}.csv; asserts AC-2.- 26 unit tests in
test_registration_classifier.py(including attitude round-trips for ±30° roll/pitch, the reproducibility check on the real first 100 IMU rows, and the boundary ratio cases).
AZ-413 — FT-P-05 + FT-P-06 cross-domain MRE budgets (3pt)
runner/helpers/mre_evaluator.py— three independent reports:PerImageBudgetReport(FT-P-05 AC-2: every MRE < 2.5 px, strict <),P95Report(single-domain p95 < budget),CombinedP95Report(FT-P-06 AC-4: both domains pass). The 95th percentile usesnumpy.percentile(..., method='linear')— exactly what the spec mandates.load_frame_to_frame_csvraisesValueErrorif the FT-P-04 CSV lacks anmre_pxcolumn (forces the failure to surface at the SUT-contract layer rather than silently passing).tests/positive/test_ft_p_05_sat_anchor.py— gated scenario that pushes the 60 images, joins MRE with GT-error viaaccuracy_evaluator.evaluate, emitsft-p-05.csv, asserts AC-2 + AC-3.tests/positive/test_ft_p_06_mre_budgets.py— pure piggyback that readsft-p-04-*.csv+ft-p-05-*.csvfrom the same run and asserts AC-4. Skips (does NOT fail) if either upstream CSV is missing — that failure mode is the FT-P-04 / FT-P-05 scenario's responsibility.- 22 unit tests in
test_mre_evaluator.py.
Files added / modified
Added (9)
AZ-409:
e2e/runner/helpers/accuracy_evaluator.pye2e/tests/positive/test_ft_p_01_still_image_accuracy.pye2e/_unit_tests/helpers/test_accuracy_evaluator.py
AZ-412:
e2e/runner/helpers/registration_classifier.pye2e/tests/positive/test_ft_p_04_derkachi_f2f_registration.pye2e/_unit_tests/helpers/test_registration_classifier.py
AZ-413:
e2e/runner/helpers/mre_evaluator.pye2e/tests/positive/test_ft_p_05_sat_anchor.pye2e/tests/positive/test_ft_p_06_mre_budgets.pye2e/_unit_tests/helpers/test_mre_evaluator.py
Modified (2)
e2e/_unit_tests/test_directory_layout.py— added 3 helper paths and 4 scenario paths (the FT-P-01/04/05/06 scenarios; FT-P-02 + FT-P-03/14 were added in batch 69)._docs/_autodev_state.md— batch 70 pointer.
Spec / module-layout drift notes
- AZ-409 AC-5 says "four times" (the 4-variant matrix); the conftest
currently parameterises
(fc_adapter, vio_strategy)as 2 × 3 = 6 variants (vins_monowas added in AZ-406 alongsideokvis2andklt_ransac). AC-5 reads "the conftest's(fc_adapter, vio_strategy)parameterization" first, with the 4-variant list as an example — so the conftest is authoritative. No code change needed; flagged here so the audit trail sees the discrepancy. - AZ-412 / AZ-413 same observation — both ACs say "per parameterization" without pinning a count; the conftest's 6-variant matrix is what runs.
- AZ-412 attitude convention — the helper docstring records the Z-down + accel-decomposition assumption explicitly (the SCALED_IMU2 wire format doesn't ship attitude). Roll/pitch ±30° round-trips are tested to confirm the decomposition.
- AZ-412 ground footprint — default 147 m is derived from
camera_info.md(~141 m alt, ~55° HFOV). Recorded as a module constant + classifier kwarg so a future re-calibration touches one place. - AZ-413 strict
<boundary — AC-2 says "MRE < 2.5 px"; the helper uses<(not≤), and the unit testtest_evaluate_per_image_budget_single_fail_fails_overallproves a 2.5 px reading FAILS. Removes the boundary ambiguity.
Test Results
Focused tests (Step 6.4)
pytest e2e/_unit_tests/ — 325 passed in 172.07s (was 248 at end
of batch 69; +77 new tests across this batch).
Breakdown of new tests:
- AZ-409 — 20 tests
- AZ-412 — 26 tests
- AZ-413 — 22 tests
- AZ-409/412/413 directory_layout entries — 9 new parametrize cases
Scenario collection: 6 scenario files × parametrize matrix yields 42
collected items in e2e/tests/positive/ (all 4 new scenario files plus
the 2 from batch 69). Every scenario file remains correctly skip-gated;
no premature activation.
No full-project pytest run
Per the implement skill's Test-Run Cadence, Step 16 owns the only full-project suite invocation; batches run focused tests only.
AC Test Coverage
See reviews/batch_70_review.md for the per-AC traceability table. In
summary: every unit-testable AC is covered; every runtime-only AC
(end-to-end harness loop) is documented as gated and auto-activating
when the upstream helpers land.
Code Review Verdict
Self-reviewed — PASS. See reviews/batch_70_review.md for the full
sweep (no Critical / High / Medium / Low findings).
Auto-Fix Attempts
- No code-review failures — auto-fix gate was not entered.
Stuck Agents
None.
Deferred follow-ups
Unchanged from batch 69 (same list, same owners):
runner.helpers.frame_source_replay.FrameSourceReplayer.{replay_video, replay_image_directory}— owned by AZ-441.runner.helpers.fdr_reader.iter_records— owned by AZ-441.runner.helpers.imu_replay.ImuReplayer.replay— owned by AZ-407 per scaffold docstring (not landed yet).runner.helpers.sitl_observer.get_observer— owned by AZ-416 / AZ-417.runner.helpers.mavproxy_tlog_reader.iter_messages— owned by AZ-416.
This batch did not introduce any new debt.
Next Batch
Batch 71 candidate set (all are 3pt scenario tasks unblocked by this batch's helpers + existing AZ-407 fixtures):
- AZ-414 (FT-P-07 + FT-N-02 — sharp-turn behaviour)
- AZ-415 (FT-P-08 — multi-segment relocalisation)
- AZ-418 (FT-P-10 — smoothing lookback) — 3pt
Likely composition: ~9 cp across 3 tasks, same shape as batches 69–70.
The next milestone after batches 71–72 will be the K=3 cumulative
review covering batches 70, 71, 72 (the current last_cumulative_review